TM2I - AC Current Isolated Transducers - RMS
Alternating current transducer
Self supplied auxiliary
Single phase AC
Accuracy 0.5 (20....120%.In)
Current input 1, 1.2, 5 or 6A
Current or voltage analogue output
Unit Dimensions : H=89mm, W=35.6mm, D=65mm
|
Availability
Range Stocked
|
|
TM3I - AC Current Isolated Transducer - RMS
Alternating current transducer
Choice of supply voltages
Single phase AC
Accuracy 0.5 (0…120%In)
Current input 1, 1.2, 5 or 6A
Dip switch programmable current or voltage analogue output
Unit Dimensions : H=89mm, W=35.6mm, D=65mm
|
Availability
Range Stocked
|
|
TM4I - AC Current Isolated Transducers - True RMS
Alternating current transducer
Choice of supply voltages
Single phase AC
True R.M.S measurement
Accuracy 0.5 (0…120%In)
Current input 1, 1.2, 5 or 6A
Dip switch programmable current or voltage analogue output
Unit Dimensions : H=89mm, W=35.6mm, D=65mm
|
Availability
Range Stocked
|
|
TM2U - AC Voltage Isolated Transducer - RMS
Alternating voltage transducer
Self supplied auxiliary
Choice of input (see table below)
Single phase AC
Current or voltage output
Accuracy 0.5 (20...120%Un)
Current or voltage analogue output
Unit Dimensions : H=89mm, W=35.6mm, D=65mm
|
Availability
Range Stocked
|
|
TM3U - AC Voltage Isolated Transducer - RMS
Alternating voltage transducer
Choice of supply voltage
Single phase AC
Choice of input (see table below)
Accuracy 0.5 (0...120%Un)
Dip switch programmable current or voltage analogue output
Unit Dimensions : H=89mm, W=35.6mm, D=65mm
|
Availability
Range Stocked
|
|
TM4U - AC Voltage Isolated Transducers - True RMS
True RMS voltage transducer
Choice of supply voltage
Single phase AC
True R.M.S measurement
Accuracy 0.5 (0...120%Un)
Dip switch programmable current or voltage analogue output
Unit Dimensions : H=89mm, W=35.6mm, D=65mm
|
Availability
Range Stocked
|
|
TM8P - Programmable Isolated Transducer - True RMS
The TM8P is a programmable transducer that can be used to measure apparent reactive - active power, power factor, phase angle, average power and frequency.
Unit Dimensions : H=89mm, W=140mm, D=65mm
|
Availability
Range Stocked
|
|
TM1A and TM1V - DC Current and Voltage Isolated Transducers
Direct connected DC current and voltage transducers
DC current transducer TM1A
DC voltage transducer TM1V
Choice of supply voltage
Accuracy 0.5
Input current 0…500µA up to 0…1.5Adc - bidirectional from ± 250µA to ± 750mA
Input voltage 0…10V up to 0…600Vdc - bidirectional from ± 5mA to ± 300V
Choice of output 0…20mA, 4…20mA, 0…10Vdc
6 module DIN rail mounting
Unit Dimensions : H=89.5mm, W=105mm, D=69mm
|
Availability
|
|
TM2G - DC Current and Voltage Signal Separator Transducers
The TM2G is a direct connected DC signal separator. Ratio 1:1.
DC current/voltage transducer
Choice of supply voltage
Accuracy 0.5
Input current 4…20mA - unidirectional (or other value on request from 1…500mA)
Input voltage 0…60mV - unidirectional (or other value on request from 50mV…400V)
Choice of output 0…5mA, 0…10mA, 0…20mA, 4…20mA
4 module DIN rail mounting
Unit Dimensions : H=89.5mm, W=70mm, D=69mm
|
Availability
To Order
|
|
TM1G - DC Direct Current Signal Separator
Direct connected DC current signal separator.
Ratio 1:1.
Self supplied.
Unit Dimensions : H=89.5mm, W=70mm, D=69mm
|
Availability
|
|
TM3G - Active Signal Separators
DIN rail mounting electronic galvanically isolated transducer.
Auxiliary supply 230Vac, 115Vac and 20…150Vdc
Inputs 0…5mA, 0…20mA or 4…20mA
Outputs 0…5mA, 0…20mA, 4…20mA or 10V.
Unit Dimensions : H=89.5mm, W=70mm, D=69mm
|
Availability
To Order
|